        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "228", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "295", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "870", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4100", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1075", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "99.99", 
                "element": "Al"
            }
        ], 
        "names": [
            "Aluminium", 
            "Aluminium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "205", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "228", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "315", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "225", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "45", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "bal", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "1", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "0.05", 
                "element": "Mg"
            }, 
            {
                "actualWeightPercent": "0.05", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "1", 
                "element": "Si"
            }, 
            {
                "actualWeightPercent": "0.05", 
                "element": "Zn"
            }
        ], 
        "names": [
            "(1 C) 1100-0", 
            "Aluminium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "170", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "158", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "143", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "117", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "58", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": ",,", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.12", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "1.2", 
                "element": "Mn"
            }
        ], 
        "names": [
            "(N3) 3003 F", 
            "Aluminium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "118", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "68", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "46", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "26", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": ",,", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "6.3", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "0.02", 
                "element": "Mg"
            }, 
            {
                "actualWeightPercent": "0.3", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "0.20", 
                "element": "Si"
            }, 
            {
                "actualWeightPercent": "0.1", 
                "element": "Zn"
            }
        ], 
        "names": [
            "2219 T81", 
            "Aluminium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "110", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "92", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "66", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "39", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "17", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "3.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": ",,", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.15", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "0.1", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "4.5", 
                "element": "Mg"
            }, 
            {
                "actualWeightPercent": "0.7", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "0.4", 
                "element": "Si"
            }, 
            {
                "actualWeightPercent": "0.25", 
                "element": "Zn"
            }
        ], 
        "names": [
            "(N8) 5083 0", 
            "Aluminium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "150", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "96", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "64", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "30", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "14.7", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": ",,", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "0.1", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "2.8", 
                "element": "Mg"
            }, 
            {
                "actualWeightPercent": "0.25", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Si"
            }, 
            {
                "actualWeightPercent": "4", 
                "element": "Zn"
            }
        ], 
        "names": [
            "7039 T61", 
            "Aluminium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "400", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "480", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1230", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "3700", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1450", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "99.96", 
                "element": "Cu"
            }
        ], 
        "names": [
            "Copper", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "395", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "445", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "880", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1320", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "325", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "99.95", 
                "element": "Cu"
            }
        ], 
        "names": [
            "ETP Cu", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "400", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "460", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "750", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "900", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "200", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "99.95", 
                "element": "Cu"
            }
        ], 
        "names": [
            "OFHC Cu", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "106", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "92", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "70", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "45", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "21", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "70", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "30", 
                "element": "Zn"
            }
        ], 
        "names": [
            "Brass", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "113", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "59", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "65", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "35", 
                "element": "Zn"
            }
        ], 
        "names": [
            "Brass", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "31", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "14", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "90", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "10", 
                "element": "Ni"
            }
        ], 
        "names": [
            "Cupro-nickel", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "23", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "20", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "62", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "15", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "22", 
                "element": "Zn"
            }
        ], 
        "names": [
            "German Silver", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "24", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "10", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "98", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "2 Be", 
                "element": "Other"
            }
        ], 
        "names": [
            "Copper Beryllium", 
            "Copper alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "94", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "115", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "154", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "320", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "865", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "138", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "99.99", 
                "element": "Ni"
            }
        ], 
        "names": [
            "Nickel", 
            "Nickel alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "10", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "8.7", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.9", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.04", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "15", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "7", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.7", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "73", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.3", 
                "element": "Si"
            }, 
            {
                "actualWeightPercent": "2.5 Ti", 
                "element": "Other"
            }
        ], 
        "names": [
            "Inconel X", 
            "Nickel alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "17", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "14", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "12", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "3", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.15", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "30", 
                "element": "Cu"
            }, 
            {
                "actualWeightPercent": "1", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.6", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "65", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.15", 
                "element": "Si"
            }
        ], 
        "names": [
            "K. Monel", 
            "Nickel alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "9.9", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "8", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "6.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "0.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.15", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "22", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "24", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "45", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "9 Mo", 
                "element": "Other"
            }
        ], 
        "names": [
            "Hastelloy X", 
            "Nickel alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "10", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "8.7", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "7", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4.8", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2.6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "0.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.4", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.04", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "18.6", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "18.5", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "1 Ti, 5 Nb, 3 Mo", 
                "element": "Other"
            }
        ], 
        "names": [
            "Inconel 718 ", 
            "Nickel alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "76", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "83.6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "95", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "109", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "65", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "13", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.02", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "99.8", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.03", 
                "element": "Mn"
            }
        ], 
        "names": [
            "Armco iron", 
            "Steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "38", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "33", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.1", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "bal", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.8", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "2.5", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Si"
            }
        ], 
        "names": [
            "2.5% Ni ", 
            "Steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "34", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "29", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "21", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.1", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.8", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "3.5", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Si"
            }
        ], 
        "names": [
            "3.5% Ni", 
            "Steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "31", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "26", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "19", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "10.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.1", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.8", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "5", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Si"
            }
        ], 
        "names": [
            "5% Ni", 
            "Steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "28", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "23", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "16", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "8.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "3.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.1", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.8", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "9", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Si"
            }
        ], 
        "names": [
            "9% Ni", 
            "Steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "13.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "7.7", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1.6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.07", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.4", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "36", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Si"
            }
        ], 
        "names": [
            "Invar 36% Ni", 
            "Steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "14.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "9", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "5.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "0.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.05", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "18", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "bal", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "2", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "812", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "1", 
                "element": "Si"
            }
        ], 
        "names": [
            "304/306/321/347", 
            "Stainless steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "8.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "6.9", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1.7", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.2", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "25", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "2", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "20", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "1.5", 
                "element": "Si"
            }
        ], 
        "names": [
            "310", 
            "Stainless steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "13.6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "9.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "0.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.01", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "16.2", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "1.2", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "20.2", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.28", 
                "element": "Si"
            }
        ], 
        "names": [
            "16 Cr, 20 Ni", 
            "Stainless steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "11.2", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "7.6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2.2", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "0.05", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "15", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": ",,", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "1.4", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "26", 
                "element": "Ni"
            }, 
            {
                "actualWeightPercent": "0.4", 
                "element": "Si"
            }, 
            {
                "actualWeightPercent": "1.3 Mo, 0.3 V", 
                "element": "Other"
            }
        ], 
        "names": [
            "15 Cr, 26 Ni", 
            "Stainless steels"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "22", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "26", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "31", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "40", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "28", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "14", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "4", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "99.9 Ti", 
                "element": "Other"
            }
        ], 
        "names": [
            "Titanium", 
            "Titanium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "7.8", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "6.1", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4.8", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "3.6", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "5", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.1", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "0.4", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "0.2", 
                "element": "Mn"
            }, 
            {
                "actualWeightPercent": "2.5", 
                "element": "Sn"
            }
        ], 
        "names": [
            "Ti 5 Al 2.5 Sn", 
            "Titanium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "7.0", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "5.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "2.5", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1.3", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "6", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.05", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "4 V", 
                "element": "Other"
            }
        ], 
        "names": [
            "Ti 6 Al4V", 
            "Titanium alloys"
        ]
    }, 
    {
        "category": "system.chemical", 
        "properties": [
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "7.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "273.2", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "5.0", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "173", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "3.4", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "100", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "1.9", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "50", 
                        "name": "Temperature"
                    }
                ]
            }, 
            {
                "name": "Thermal conductivity, $\\lambda$", 
                "scalars": "0.9", 
                "dataType": "EXPERIMENTAL", 
                "references": [
                    {
                        "table": {
                            "caption": "Thermal conductivities of alloys used in low temperature applications", 
                            "number": "5"
                        }
                    }
                ], 
                "units": "Wm$^{-1}$K$^{-1}$", 
                "conditions": [
                    {
                        "units": "K", 
                        "scalars": "20", 
                        "name": "Temperature"
                    }
                ]
            }
        ], 
        "references": [
            {
                "url": "http://www.kayelaby.npl.co.uk/general_physics/2_3/2_3_7.html"
            }
        ], 
        "composition": [
            {
                "actualWeightPercent": "3", 
                "element": "Al"
            }, 
            {
                "actualWeightPercent": "0.08", 
                "element": "C"
            }, 
            {
                "actualWeightPercent": "11", 
                "element": "Cr"
            }, 
            {
                "actualWeightPercent": "0.3", 
                "element": "Fe"
            }, 
            {
                "actualWeightPercent": "13 V", 
                "element": "Other"
            }
        ], 
        "names": [
            "Ti 13 V 11 Cr 3 Al", 
            "Titanium alloys"
        ]
    }
]